Geocomp > Concrete > Standard Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete

Standard Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete

Test Method Title

Standard Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete

Reference Number

AASHTO T 309

Material

Field Concrete

Test Property

Temperature

Description of Test

Concrete is sampled in accordance with AASHTO R 60. The temperature of fresh concrete is measured in the field. The probe of a thermometer is inserted into freshly sampled concrete such that the probe is surrounded by at least 3-inches of concrete in all directions. The concrete is compressed around the thermometer using the fingers. The thermometer is allowed to stabilize for a minimum of 2 minutes before the reading is recorded, but within 5 minutes of obtaining the sample.

Number of Test Specimens

1

Test Specimen Size

3 gallons

Keywords

concrete, temperature