Geocomp > Geosynthetic > Geogrid Rib Tensile Strength **GRI has discontinued this method, the industry-accepted standard test method is now ASTM D6637

Geogrid Rib Tensile Strength **GRI has discontinued this method, the industry-accepted standard test method is now ASTM D6637

Test Method Title

Geogrid Rib Tensile Strength **GRI has discontinued this method, the industry-accepted standard test method is now ASTM D6637

Reference Number

GRI GG 1

Material

Geogrid

Test Property

rib tensile strength

Description of Test

The geogrid specimen (with at least three junctions) is clamped in a tensile machine and pulled to failure while recording displacement and strength. Average rib tensile strength and elongation reported.

Number of Test Specimens

5

Test Specimen Size

12" long (or at least 3 junctions)

Keywords

rib, strength, tensile