Test Method Title
Geogrid Rib Tensile Strength **GRI has discontinued this method, the industry-accepted standard test method is now ASTM D6637
Reference Number
GRI GG 1
Material
Geogrid
Test Property
rib tensile strength
Description of Test
The geogrid specimen (with at least three junctions) is clamped in a tensile machine and pulled to failure while recording displacement and strength. Average rib tensile strength and elongation reported.
Number of Test Specimens
5
Test Specimen Size
12" long (or at least 3 junctions)
Keywords
rib, strength, tensile